Skip to content
Engineering sprint

Unit Rush · an engineering unit conversion game

Convert psi to kPa, hp to kW and volts to amps against a 60-second clock. Build a combo, and see the exact factor behind every slip.

How to play

Each card asks for one quantity, such as 10 hp in kilowatts or the current through a resistor. Four values sit on a number line, smallest first. Tap the right one or press 1 to 4. Three right in a row starts a combo that multiplies your points. A wrong pick costs two seconds and shows the mistake that produces that value.

Say a card asks for 10 hp in kW. One horsepower is 0.7457 kW, so the answer is 7.46. The 13.4 beside it is the factor turned the wrong way, and 0.746 is a slipped decimal point. Every wrong value comes from a real mistake. A quick sense of direction and size often rules out two before you calculate anything.

Everyone gets the same daily cards until midnight UTC, and your first run of the day counts. Sprint 60 deals fresh cards every time. Endless gives each card a shrinking fuse, and three wrong answers end the run. Pick a deck for Ohm's law and power, torque and mechanics, or US and metric units. The factors come from NIST Special Publication 811.

Which conversion factors does it use?

Every factor comes from NIST Special Publication 811, Appendix B.9, printed as NIST gives it or worked out from NIST's figures where the note says how. Each card shows its arithmetic with these numbers, and every answer to three significant figures. A factor marked exact is exact by definition.

The conversions in the deck
OneEquals
1 psi6.894757 kPa
1 bar14.50377 psi (100 kPa ÷ 6.894757)
1 ksi6.894757 MPa
1 in25.4 mm (exact)
1 ft0.3048 m (exact)
1 mi1.609344 km (exact)
1 lb0.45359237 kg (exact)
1 lbf4.448222 N
1 kip4.448222 kN
1 hp0.7456999 kW
1 BTU/h0.2930711 W
1 ton of refrigeration3.516853 kW
1 kWh3,412.141 BTU (3,600 kJ ÷ 1.055056)
1 kWh3.6 MJ (exact)
1 lbf·ft1.355818 N·m
1 lbf·in0.1129848 N·m
1 gal3.785412 L
1 gpm3.785412 L/min
1 ft³28.31685 L
1 ft²0.09290304 m² (0.3048², exact)
1 in²645.16 mm² (25.4², exact)
1 ft of water0.4335149 psi (water at 39.2 °F: 2,988.98 Pa ÷ 6,894.757)

Temperature uses °F = °C × 1.8 + 32, and a change of 1 °C is a change of 1.8 °F.

Which formulas are on the electrical and mechanical cards?

The electrical cards use the SI definitions in NIST Special Publication 330: one ohm is one volt per ampere and one watt is one volt-ampere. So V = I × R, and power is P = V × I = I² × R = V² ÷ R. Two resistors in parallel combine as R₁R₂ ÷ (R₁ + R₂).

The mechanical cards use torque T = F × r and pressure p = F ÷ A, with a cylinder bore's area π × d² ÷ 4. Weight is mass × 9.80665 m/s², the standard acceleration of gravity. Shaft power follows from P = T × ω, with ω = 2π × rpm ÷ 60. One horsepower is 550 ft·lbf per second, so hp = lbf·ft × 2π × rpm ÷ 33,000, the shop rule's lbf·ft × rpm ÷ 5252; in SI units, kW = N·m × 2π × rpm ÷ 60,000, or N·m × rpm ÷ 9549. A driven gear turns at rpm₁ × T₁ ÷ T₂.

The numbers on the cards are practice values. Check a real installation against its own specifications and the code that applies to it.

How is a run scored?

A right card earns 100 points times the combo: ×2 from three in a row, ×3 from six and ×4 from ten. A wrong pick resets the combo. In a timed run it also takes two seconds off the clock, and in Endless it burns one of three fuses. Your first daily run counts and is saved as you play it, so a reload goes back to it; replays and your best Sprint and Endless scores stay in this browser too.